Magnamed Fleximag Max Ventilator has safety and accuracy as the basic features, in addition to the simple and intuitive interface that facilitates the complex routine of the Neonatal ICU. It supports the development of neonatal and pediatric patients with advanced technology and has Non-invasive Ventilation for all the ventilator modes and the use of CPAP with a respiratory rate adjustment.
Magnamed Fleximag Max Ventilator Highlights
02 THERAPY
With the high flow adjustment and predetermined 0 concentrations, the system guarantees more comfort to the patient and reduces the risk of new intubations. Adapted to suit all types of patients
NIV
Whether in the ICU or in an emergency room, non-invasive ventilation is a good alternative in situations where it is possible to avoid intubation, thus reducing the risk of infections and the length of hospital stay.
INTERFACE
Based on a study carried out with users, the FlexiMag Max interface was developed to allow intuitive and configurable operation according to the routine of your ICU.
PROTECTIVE MONITORING
In order to optimize, protect and individualize pulmonary ventilation, with a focus on the patient and his pathology, Protective Monitoring allows continuous assessment and a better ventilation strategy
- High-performance ventilation for adults, children, and newborns.
- 02 therapy. Greater patient comfort and less risk of new intubations.
- Advanced monitoring tools. such as capnography and oximetry.
- Driving Pressure monitoring.
- Advanced communication system:
- USB, HL7 protocol, and nursing call. Memorization of the last 240 hours of ventilation.
Technical Specifications
Parameters Adjustments
- Type of patient Adult, Pediatric and Neonatal
- Tidal volume 2 to 3.000 ml
- Respiratory rate 0 to 200 rpm
- lnspiratory flow 1 to 180 L/min
- Rise time 0 to 2,0 s lnspiratory time 0,05 to 30 s
- lnspiratory pressure 0 to 120 cmH2O [or hPa or mbar]
- Peep 0 to 50 cmH2O [or hPa or mbar]
- Support Pressure/lips 0 to 120 cmH2O lor hPa or mbarl
- Flow cycling [% of peak flow] 5 to 80 %
- Pressure trigger 0.0 to 20 cmH2O (or hPa or mbar)
- Flow trigger 0,0 to 30 L/min
- Ratio l:E 1 :599 to 299: 1
- 02 concentration 21 to 100%
- Type of inspiratory flow Constant, decelerating, accelerating and sine
- lnspiratory and expiratory pause 0,1 to 30 s
Alarms
- Minute volume / Total volume high / low
- Respiratory rate high / low
- Maximum pressure high / low
- Peep high / low
- Apnea time OFF, 0 to 60 s
- Automatic alarm ajustments OFF. 10%, 20% and 30%
- Driving Pressure high / low
Ventilation Modes
VCV /VCV-AC: PCV / PCV-AC: PRVC: PLV: PLV-AC; VG; V-SIMV + PS: P-SIMV + PS; DualPAP / APRV; CPAP/PSV; MMV: VS: CPAP NASAL: VNI; O2 THERAPY
Monitoring
- Curve PxT, FxT and VxT / SpO2/ CO2
- Loops PxF, VxF. PxV, VxCO2. VxFCO2
- Different colors lnsp. and exp. phases, trigger modes and windows
- Bargraph Instant pressure
- Optional monitoring Capnography or Oximetry
- Numerical value Tidal volume and Minute volume; Respiratory rate; inspiratory and expiratory time; Max and mean plateau pressure and plateau pressure; Peep; Ratio l:E; Protective Monitoring; Driving Pressure; O2 consumption.
User Interface
- Type and Size TFT-LCD touchscreen 15″
- Weight 23 kg
- Dimensions W x H x D 453 x 1427 x 544mm
- Communication/Interface Emergency call, HDMl, USB, Ethernet RJ-45. RS 232. Hl7
- Remote Technical Assistance Magnamed Remote Assistance IARM]
Operating Conditions Specifications
- Electrical power supply 100 to 240 V, 50/60 Hz 12
- Voe external yes [optional]
- Battery 210 minutes
- 02 inlet 29 to 87 psi [200 to 600 kPa]
- AR gas inlet 29 to 87 psi [200 to 600 kPa]
- Temperature -10 to 50°C [14 to 122°F]
- Barometric pressure 525 to 1.200 cmH20 [or hPa or mbar]
- Relative humidity 15 to 95%
Other operations
- Nebulizer Synchronized with inspiration
- Tracheal gas insufflation [TGI] Synchronized with expiration
- Trend 240h
- Volume compensation – BTPS temperature and humidity
- Auxiliary pressure Using esophageal balloon or pressure measurement at the carina
General Specifications
- Stand by on/off
- Manual cycles yes
- Graphic freeze yes
- Sigh yes
- Flow sensor Proximal or Distal
- Turbine [Flow Air] Max 300 / Max 700
Brand Warranty – 1 Year
Country Of Origin – Brazil
AMC Options Available Contact Support For More
Reviews
There are no reviews yet.